Unlike conventional chlorination systems, CHLOREFS direct electrolysis units are not classified as hazardous production facilities. Conventional systems typically operate with liquid chlorine or rely on facilities for the storage and dosing of commercial (technical-grade) sodium hypochlorite solutions with concentrations of 12–16%. Consequently, CHLOREFS units are not considered environmentally hazardous and fully comply with current industrial safety regulations governing chlorine-containing processes.
Direct electrolysis units generate the disinfectant – sodium hypochlorite – directly from the water being treated, using naturally occurring chlorides present in the source water. No external oxidizing agents are introduced into the water during the process.
For the disinfection of artesian or surface water using direct electrolysis, only an electrolyzer and a power supply unit are required. This eliminates the need for transportation, storage, and dosing of chlorine-based or other chemical reagents.
CHLOREFS UGPE direct electrolysis units are specifically designed for final-stage water disinfection, particularly in the following configuration:
Artesian well → UGPE direct electrolysis unit → elevated water tower → distribution network
Compared to other water disinfection methods, direct electrolysis units offer significant economic advantages for:
small towns and rural settlements;
health resorts, medical and wellness facilities;
sanatoriums and recreational centers;
military facilities;
swimming pools and water parks.
Direct electrolysis units are equipped with an automatic monitoring system that controls the following parameters:
electric current;
voltage;
temperature;
treated water flow;
total electrolysis operating time.
|
No. |
Equipment Description |
Qty |
|
1 |
Acid cleaning circuit (100 L tank with Flux 315 pump) |
1 |
|
2 |
Flow-through electrolyzer |
1 |
|
3 |
Inverter-type power supply unit |
1 |
|
4 |
Control pannel* |
1 |
|
5 |
Flow switch and temperature sensor |
1 |
|
6 |
Piping, shut-off and control valves set |
1 |
|
7 |
Cable set and cable management systems |
1 |
|
8 |
Mounting frame for electrolyzer and power supply unit |
1 |
|
UGPE-300 |
UGPE-600 | UGPE-1200 | UGPE-2400 | |
|
Operating mode |
Continuous | Continuous | Continuous | Continuous |
|
Nominal output (available chlorine as Cl₂), g/day |
250–300 | 550-600 | 1,150-1,200 | 2,350-2,400 |
|
Inlet water parameters |
UGPE-300 | UGPE-600 | UGPE-1200 | UGPE-2400 |
|
Water temperature, °C |
10-25 | 10-25 | 10-25 | 10-25 |
|
Chloride concentration, mg/L (minimum) |
20 | 20 | 20 | 20 |
|
Power supply parameters |
UGPE-300 | UGPE-600 | UGPE-1200 | UGPE-2400 |
|
Supply voltage, V |
220 ±10% | 220 ±10% | 220 ±10% | 220 ±10% |
|
Frequency, Hz |
50 ±1 | 50 ±1 | 50 ±1 | 50 ±1 |
|
Operating current, A |
20 | 40 | 80 | 160 |
|
Electrolyzer operating voltage, V |
from 12 | from 24 | from 32 | from 32 |
|
Power consumption, kW |
up to 0.3 | up to 1.0 | up to 2.5 | up to 0.3 |